Item No. element
|
Standard/method, testing time, devices included
|
Range accuracy
|
|
|
GDYS-101SB Colority
|
GB/T5750.4-2006
Meter, Colorimetric device
|
5-200PCU
accuracy5%
|
|
|
GDYS-101SC O3
|
DPD 3Minutes
Meter,
Colorimetric device,
reagent: 50 times
|
0.05-2.50mg/L
accuracy3%
|
|
GDYS-101SE CLO2
|
DPD 3Minutes
Meter,
Colorimetric device,
reagent: 50 times
|
0.01 -3.00mg/L
accuracy5%
|
|
GDYS-101SF Fluoride
|
GB/T5750.5-2006 30minutes
Meter,
Colorimetric device,
reagent: 50 times
|
0.01-1.00mg/L
accuracy5%
|
|
GDYS-101SG Cr6+
|
GB5750.6-2006 3minutes
Meter,
Colorimetric device,
reagent: 50 times
|
0.01-1.00mg/L
accuracy5%
|
|
GDYS-101SI Ca
|
CPPI 3 minutes
Meter,
Colorimetric device,
reagent: 50 times
|
0.10-2.00mg/L
accuracy3%
|
|
GDYS-101SL Total P
|
GB11906-89 20 minutes
Meter,
Colorimetric device,
Digestion thermostat device,
Sample pretreatment device
reagent: 50 times
|
0.02-1.00mg/L
accuracy5%
|
|
GDYS-101SM Mn
|
GB/T5750.6-2006 10 minutes Meter,
Colorimetric device,
reagent: 50 times
|
0.50-4.00mg/L
accuracy5%
|
|
|
GDYS-101SN total cl, residual cl
|
GB/T5750.11-2006 3minutes
Meter,
Colorimetric device,
reagent: 50 times
|
0.05-9.99mg/L
accuracy5%
|
|
GDYS-101SN2 residual cl
|
3minutes
Meter,
Colorimetric device,
reagent: 50 times
|
0.05-5.00mg/L
accuracy5%
|
|
GDYS-101SR Dissolved oxygen
??/span>
|
DL 3minutes
Meter,
pretreatment device,
reagent 30 times
|
0.1-10.0mg/L
accuracy5%
|
|
GDYS-101ST Fe
|
GB/T5750.6-2006 30minutes
Meter,
pretreatment device,
reagent 50 times
|
0.1-3.0mg/L
accuracy 5%
|
|
GDYS-101SV sulfide
|
GB/T5750.6-2006 10minutes
Meter,
pretreatment device,
reagent 50 times
|
0.02-1.00mg/L
accuracy5%
|
|
GDYS-101SW Al
|
10minutes
Meter,
pretreatment device,
reagent 50 times
|
0.01-1.00mg/L
accuracy5%
|
|
GDYS-101SY total cl, residual cl
|
GB/T5750.11-2006 3minutes
Meter,
Colorimetric device,
reagent: 50 times
|
0.05-9.99mg/L
accuracy5%
|
|
GDYS-101SZ Turbidity
|
GB/T5750.4-2006 3minutes
Meter,
Colorimetric device,
|
5-400NTU
accuracy5%
|
|
|
GDYS-101SZ2 Turbidity
|
GB/T5750.4-2006 3minutes
Meter,
Colorimetric device,
|
0.5-60.0NTU
accuracy5%
|
|
|
GDYS-102SB Total hardness
|
5minutes
Meter,
Colorimetric device,
reagent:50 times
|
25-750.0mg/L
accuracy5%
|
|
GDYS-102SC H2O2
|
10minutes
Meter,
Colorimetric device,
reagent:50 times
|
5.0-300.0mg/L
accuracy5%
|
|
GDYS-102SD HCHO
|
45minutes
Meter,
Colorimetric device,
reagent:50 times
|
0.01-1.00mg/L
accuracy5%
|
|
|
meter
|
0.2-28.0%
accuracy±2%
|
|
|
GDYS-102SH Sulfate
|
5minutes
Meter,
Colorimetric device,
reagent:50 times
|
2.0-20.0mg/L
accuracy5%
|
|
|
GDYS-102SJ Urea
|
50minutes
Meter,
Colorimetric device,
reagent:50 times
|
0.5-10.0mg/L
accuracy5%
|
|
|
GDYS-102SL Chloride
|
5minutes
Titration device
Reagent: 50 times
|
20-500.0mg/L
accuracy5%
|
|
|
GDYS-102SL2 Chloride
|
5minutes
Meter,
Colorimetric device,
reagent:50 times
|
0.5-4.0mg/L
accuracy5%
|
|
GDYS-102SM Peroxyacetic acid
|
1minutes
Meter,
Colorimetric device,
reagent:50 times
|
1.0-10.0mg/L
accuracy5%
|
|
GDYS-102SN Cu
|
3minutes
Meter,
Colorimetric device,
reagent:50 times
|
0.05-1.00mg/L
accuracy5%
|
|
GDYS-102SO Zn
|
5minutes
Meter,
Colorimetric device,
reagent:50 times
|
0.05-3.00mg/L
accuracy5%
|
|
GDYS-102SP B
|
40minutes
Meter,
Colorimetric device,
reagent:50 times
|
0.3-15.0mg/L
accuracy5%
|
|
GDYS-102SQ Cyanide
|
30minutes
Meter,
Colorimetric device,
reagent:50 times
|
0.03-1.00mg/L
accuracy5%
|
|
GDYS-102SQ2 CClN
|
5minutes
Meter,
Colorimetric device,
reagent:50 times
|
0.03??/span>0.50mg/L???CN???
accuracy5%
|
|
GDYS-102SR SiO2
|
20minutes
Meter,
Colorimetric device,
reagent:50 times
|
1.0-20.0mg/L
accuracy5%
|
|
GDYS-102ST K
|
20minutes
Meter,
Colorimetric device,
reagent:50 times
|
30-100.0mg/L
accuracy5%
|
|
GDYS-102ST2 K
|
Meter,
Colorimetric device,
reagent:50 times
|
1.0-20.0mg/L
accuracy5%
|
|
GDYS-102SU Mo
|
40minutes
Meter, Colorimetric device, reagent:50 times
|
0.01-1.00mg/L
accuracy5%
|
|
GDYS-102SV Hg
|
10minutes
Meter,
Colorimetric device,
reagent:50 times
|
0.1-0.5mg/L
accuracy5%
|
|
GDYS-102SW Ag
|
30minutes
Meter,
Colorimetric device,
reagent:50 times
|
0.05-1.00mg/L
accuracy5%
|
|
GDYS-102SX ??/span>Cobalt Co
|
30minutes
Meter, Colorimetric device, reagent:50 times
|
0.01-0.50mg/L
accuracy5%
|
|
GDYS-102SY Phosphate
|
15minutes
Meter,
Colorimetric device,
reagent:50 times
|
0.1-1.0mg/L
accuracy5%
|
|
GDYS-102SZ2 Ni
|
Meter,
Colorimetric device,
reagent:50 times
|
0.05-1.00mg/L
accuracy5%
|
|
|
GDYS-103SA2 As
|
60minutes
Meter,
Colorimetric device,
reagent:50 times
|
0.006-1.000mg/L
accuracy5%
|
|
|
GDYS-103SB2 Cd
|
Meter,
Colorimetric device,
reagent:50 times
|
0.01-1.00mg/L
accuracy5%
|
|
|
GDYS-103SC Pb
|
5minutes
Meter,
Colorimetric device,
reagent:50 times
|
0.5-3.0mg/L
accuracy5%
|
|
|
GDYS-103SE Mg
|
5minutes
Meter,
Colorimetric device,
reagent:50 times
|
0.2-20.0mg/L
accuracy5%
|
|
|
GDYS-103SI Total Alkalinity
|
10 minutes
Titration device,
reagent: 50 times
|
10-1000.0mg/L
accuracy5%
|
|
|
GDYS??span lang="EN-US">103SM Br
|
10minutes
Meter,
Colorimetric device,
reagent:50 times
|
0.1-3.0mg/L
accuracy5%
|
|
|
GDYS??/span>103SN Hydrogen sulfide H2-S
|
20minutes
Meter,
Colorimetric device,
sample pretreatment device, reagent:50 times
|
0.01-1.00mg/L
accuracy5%
|
|
|
GDYS??/span>103SO Pd
|
10minutes
Meter, Colorimetric device, reagent:50 times
|
0.5-1.0mg/L
accuracy5%
|
|
|
GDYS-103SP Se
|
20minutes
Meter,
Colorimetric device,
reagent:50 times
|
0.5-1.0mg/L
accuracy5%
|
|
|
GDYS??/span>103SQ Ba
|
10minutes
Meter,
Colorimetric device,
reagent:50 times
|
1.0-7.0mg/L
accuracy5%
|
|
|
GDYS??/span>103SR Cyanuric acid
|
15minutes
Meter, Colorimetric device, reagent:50 times
|
5.0-30.0mg/L
accuracy5%
|
|
|
GDYS-103SW C6H6
|
Meter,
Colorimetric device,
reagent:50 times
|
0.25-2.50mg/L
accuracy10%
|
|
|
GDYS-103SX Cr3+
|
Meter,
Colorimetric device,
reagent:50 times
|
5.0-30.0mg/L
accuracy5%
|
|
|
GDYS-103SY TOC
|
Meter, Colorimetric device, reagent:50 times
|
0.5-30.0mg/L ??/span>C??/span>
accuracy5%
|
|
|
GDYS-103SZ Be
|
Meter,
Colorimetric device,
reagent:50 times
|
0.001-0.100mg/L
accuracy5%
|
|
GDYS-101SQ COD
|
Sealed backflow Digesting Colorimetric method
20 minutes
Meter,
Digestion thermostat device , Colorimetric device,
sample pretreatment device, reagent:50 times
|
10—500mg/L accuracy5%
|
|
|
GDYS-101SQ2 COD
|
Sealed backflow Digesting Colorimetric method
60 minutes
Meter,
cup,
Colorimetric device,
sample pretreatment device, reagent:50 times
|
30—300mg/L accuracy5%
|